When using VOMMA software, the video stream opens and is not displayed on the interface.
2024-01-23 16:42:57
• At this time, you can click Window -> Camera Control and set the drop-down box behind the trigger mode to continuous capture;
• The cause of this issue is that the camera was previously used in the SDK and then set an external trigger or soft trigger, which saves the configuration to the camera after the camera is turned off. As a result, the triggering mode set last time is still used during the startup. This leads to "open the video stream" and then waiting for the trigger signal.
See the following figure for details of the specific steps: